Katherm HK

В наличии
Trench heating and cooling. EC cross-flow fan convection: low-noise and energy-efficient.
Производитель
Kampmann
Тип
Trench Heating

Key features

  • Short delivery times for our standard trenches
  • A matching edge profile for a perfect design with every grille
  • KaControl control system as standard; can be integrated into KaControl networks or building automation system, such as KNX, Modbus or LON
  • Cost-effective efficient heating and cooling even at low noise levels 

TECHNOLOGY

  • Energy-saving EC tangential fan with flow-optimised impellers, cascaded arrangement as a continuous fan belt; this produces uniform airflow through convector with minimal sound emissions.
  • High-performance coil optimised for airflow and heating and cooling output, with Eurokonus valve connection
  • 2-pipe or 4-pipe system for individual comfort in every room
  • Standard raised floor feet and mounting brackets with impact sound insulation for ease of installation of the trench system and avoidance of sound transfer
  • Anti-torsion mechanism for heating connections prevents damage to the convector when fitting the valves; valves optionally available as accessories
  • Specially designed condensate tray for safe removal of the condensate and simultaneous air routing; can be pulled out to the room side for ease of cleaning in line with the Hygiene Directive VDI 6022.
  • Condensate pump set (optional) to drain condensate, if needed
 


AREAS OF APPLICATION / INSTALLATION

  • Buildings of all kinds in which there is a high cooling requirement due to the sun’s rays
  • Clear view and feel good temperature in front of full-length glass façades
  • Developed to meet the requirements of a modern room air conditioning
  • 9 unit lengths, 2 unit widths, 2 unit heights; made-to-measure lengths on request


... also good to know

  • The heat outputs were measured and determined in accordance with DIN EN 16430 "Fan-assisted radiators, convectors and trench convectors" Part 1: "Technical Specifications and Requirements", Part 2: "Test method and Evaluation of Heat Output" and Part 3 "Test Method and Evaluation of Cooling Output".
  • The acoustics measurements were carried out in a semi low-reflective acoustic chamber in compliance with DIN EN ISO 3744.

  